Features
-
Big display with luminescent backlight
-
Simultaneous indication of units of measurement, measurement errors, threshold level and real time on the display
-
Analog ten-segment indicator of registered radiation intensity
-
Ability to perform measurements with a preset error
-
Four-level indication of battery discharge
-
Built-in memory which allows storing up to 1 200 measurements
-
Mode of PC connection via Bluetooth
-
Five independent measuring channels with alternate indication of data on the single liquid crystal display
-
Built-in gamma-beta-sensitive Geiger-Muller counter
-
Prompt evaluation of gamma background within 10 seconds
-
Automatic subtraction of gamma background at measurement of beta contamination
-
Measurement results averaging, manually and automatically interrupted
-
Automatic setting of measurement intervals and ranges
-
Audio, vibration and vibration-audio alarm of each detected gamma-quantum or beta-particle that can be switched off
-
Two-tone audio, vibration and vibration-audio alarm of exceeded programmed threshold levels
-
Clock and alarm clock
Specifications
Measurement range of photon-ionizing radiation DER | 0.1 … 9 999 µSv/h |
Main relative permissible error limit of photon-ionizing radiation DER measurement with confidence probability of 0.95 | (15+2/H*(10)) %,where H*(10) is a numeric value of the measured DER in μSv/h |
Measurement range of photon-ionizing radiation DE | 0.001 … 9 999 mSv |
Main relative permissible error limit of photon-ionizing radiation DE measurement with confidence probability of 0.95 | ± 15 % |
Energy range of registered photon-ionizing radiation | 0.05 … 3 MeV |
Energy dependence when measuring gamma radiation DER and DE relative to 0.662 MeV energy (137Cs) in the energy range from 0.05 to 1.25 MeV, not more | ± 25 % |
Measurement range of surface beta-particles flux density | 10 … 100 000 part./(cm²·min) |
Main relative permissible error limit of beta-particles flux density measurement with confidence probability of 0.95 | (20+200/φβ) %, where φβ is a numeric value of the measured surface flux density in part./(cm²·min) |
Energy range of registered beta-particles | 0.5 … 3 MeV |
Measurement range of DE accumulation time | 9 999 h |
Resolution of DE accumulation time display in the range- of 0 h to 100 h
– of 100 h to 9 999 h |
1 min
1 h |
Absolute permissible error limit at DE accumulation time measurement during 24 h | ± 1 min |
Time of the dosimeter operating mode setting, not more | 1 min |
Battery life (AAAx2 of 1 280 mAh capacity) under + 20 °С temperature, natural background radiation and switched off display backlight, not more | 2 000 h |
Operating supply voltage | 3 V |
Operating temperature range | – 20 … + 50 °С |
Dimensions, not more | 55 × 26 × 120 mm |
Weight, not more | 0.2 kg |